Something's wrong.

Let's find out what.

We provide diagnostics and repair engineering for solar systems of any size, from residential inverter swaps to multi-MW storm damage assessments that hold up with insurers and AHJs.

Something's wrong.

Let's find out what.

We provide diagnostics and repair engineering for solar systems of any size, from residential inverter swaps to multi-MW storm damage assessments that hold up with insurers and AHJs.

REPAIR SERVICES

Every failure mode,

covered.

Click any service to see what's included.

Inverter Diagnostics & Replacement
String, central, and microinverter fault isolation and replacement.
+

We perform live electrical testing, error-code analysis, and communication diagnostics to isolate whether the fault is firmware, hardware, or grid-side. Replacements are spec-matched and the updated single-line diagram is provided with every swap.

String inverters Central inverters Microinverters Optimizer replacement
24-48 HR DISPATCH
Module Replacement & Hot-Spot Repair
EL imaging, IV curve tracing, and module-by-module replacement.
+

Electroluminescence imaging and IV curve tracing identify cracked cells, hot spots, and PID before they cascade. Matched-spec modules are sourced and installed with torque-verified racking hardware.

EL imaging IV curve tracing Hot-spot repair Module sourcing
PER-MODULE REPORTING
DC & AC Wiring Repairs
Arc-fault mitigation, connector replacement, and conduit repairs.
+

Cross-mated connectors, UV-degraded jacketing, and undersized conduit are the most common arc-fault sources we find. We re-terminate to manufacturer spec and megger-test each string before recommissioning.

Arc-fault mitigation Re-termination Megger testing Conduit rework
NEC 690 COMPLIANT
Racking & Structural Repairs
Attachment assessment, racking replacement, and re-stamped structural letters.
+

Failed flashings, loosened attachments, and corroded rails are documented photographically, then repaired and re-certified. A PE-stamped structural letter is reissued for the as-built condition.

Flashing repair Attachment audit Rail replacement PE letters
PE-STAMPED OUTPUT
Storm Damage Assessment & Reporting
Insurance-grade damage reports with PE signature for claims and AHJ filings.
+

Post-event inspections combine drone thermography, ground survey, and production data review. The resulting report is formatted for carrier adjusters and AHJ resubmittal, with repair scope and cost basis included.

Drone thermography Carrier reporting AHJ resubmittal Scope & cost basis
72 HR TURNAROUND
Performance Restoration
Root-cause analysis for underperforming systems with a fix-or-replace recommendation.
+

We benchmark actual production against a modeled expectation, then work down from array-level to string-level to isolate losses — soiling, shading, clipping, degradation, or component failure — and quantify the payback of each fix.

Production modeling String-level analysis Soiling & shading Payback analysis
MODELED VS. ACTUAL

let's build

Stop losing money. Send us your next

project scope.

PHONE

(602) 905-3422

ADDRESS

1865 E 3rd St, Tempe, AZ 85281

let's build

Send us your next

project scope.

Preliminary layouts and pricing for qualified RFPs within two business days.

Tell us the site, the target size, and the AHJ — we'll take it from there.

PHONE

(602) 123-1234

ADDRESS

1865 E 3rd St, Tempe, AZ 85281

Copyright 2026. SONORA SOLAR ENGINEERING LLC. All Rights Reserved.